Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 216
Filtrar
1.
Cochrane Database Syst Rev ; 4: CD013271, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38597338

RESUMO

BACKGROUND: Bronchopulmonary dysplasia (BPD) remains an important complication of prematurity. Pulmonary inflammation plays a central role in the pathogenesis of BPD, explaining the rationale for investigating postnatal corticosteroids. Multiple systematic reviews (SRs) have summarised the evidence from numerous randomised controlled trials (RCTs) investigating different aspects of administrating postnatal corticosteroids. Besides beneficial effects on the outcome of death or BPD, potential short- and long-term harms have been reported. OBJECTIVES: The primary objective of this overview was to summarise and appraise the evidence from SRs regarding the efficacy and safety of postnatal corticosteroids in preterm infants at risk of developing BPD. METHODS: We searched the Cochrane Database of Systematic Reviews, MEDLINE, Embase, CINAHL, and Epistemonikos for SRs in April 2023. We included all SRs assessing any form of postnatal corticosteroid administration in preterm populations with the objective of ameliorating pulmonary disease. All regimens and comparisons were included. Two review authors independently checked the eligibility of the SRs comparing corticosteroids with placebo, and corticosteroids with different routes of administration and regimens. The included outcomes, considered key drivers in the decision to administer postnatal corticosteroids, were the composite outcome of death or BPD at 36 weeks' postmenstrual age (PMA), its individual components, long-term neurodevelopmental sequelae, sepsis, and gastrointestinal tract perforation. We independently assessed the methodological quality of the included SRs by using AMSTAR 2 (A Measurement Tool to Assess Systematic Reviews) and ROBIS (Risk Of Bias In Systematic reviews) tools. We assessed the certainty of the evidence using GRADE. We provided a narrative description of the characteristics, methodological quality, and results of the included SRs. MAIN RESULTS: We included nine SRs (seven Cochrane, two non-Cochrane) containing 87 RCTs, 1 follow-up study, and 9419 preterm infants, investigating the effects of postnatal corticosteroids to prevent or treat BPD. The quality of the included SRs according to AMSTAR 2 varied from high to critically low. Risk of bias according to ROBIS was low. The certainty of the evidence according to GRADE ranged from very low to moderate. Early initiated systemic dexamethasone (< seven days after birth) likely has a beneficial effect on death or BPD at 36 weeks' PMA (risk ratio (RR) 0.88, 95% confidence interval (CI) 0.81 to 0.95; number needed to treat for an additional beneficial outcome (NNTB) 16, 95% CI 10 to 41; I2 = 39%; 17 studies; 2791 infants; moderate-certainty evidence) and on BPD at 36 weeks' PMA (RR 0.72, 95% CI 0.63 to 0.82; NNTB 13, 95% CI 9 to 21; I2 = 39%; 17 studies; 2791 infants; moderate-certainty evidence). Early initiated systemic hydrocortisone may also have a beneficial effect on death or BPD at 36 weeks' PMA (RR 0.90, 95% CI 0.82 to 0.99; NNTB 18, 95% CI 9 to 594; I2 = 43%; 9 studies; 1376 infants; low-certainty evidence). However, these benefits are likely accompanied by harmful effects like cerebral palsy or neurosensory disability (dexamethasone) or gastrointestinal perforation (both dexamethasone and hydrocortisone). Late initiated systemic dexamethasone (≥ seven days after birth) may have a beneficial effect on death or BPD at 36 weeks' PMA (RR 0.75, 95% CI 0.67 to 0.84; NNTB 5, 95% CI 4 to 9; I2 = 61%; 12 studies; 553 infants; low-certainty evidence), mostly contributed to by a beneficial effect on BPD at 36 weeks' PMA (RR 0.76, 95% CI 0.66 to 0.87; NNTB 6, 95% CI 4 to 13; I2 = 14%; 12 studies; 553 infants; low-certainty evidence). No harmful side effects were shown in the outcomes chosen as key drivers to the decision to start or withhold late systemic dexamethasone. No effects, either beneficial or harmful, were found in the subgroup meta-analyses of late hydrocortisone studies. Early initiated inhaled corticosteroids probably have a beneficial effect on death and BPD at 36 weeks' PMA (RR 0.86, 95% CI 0.75 to 0.99; NNTB 19, 95% CI not applicable; I2 = 0%; 6 studies; 1285 infants; moderate-certainty evidence), with no apparent adverse effects shown in the SRs. In contrast, late initiated inhaled corticosteroids do not appear to have any benefits or harms. Endotracheal instillation of corticosteroids (budesonide) with surfactant as a carrier likely has a beneficial effect on death or BPD at 36 weeks' PMA (RR 0.60, 95% CI 0.49 to 0.74; NNTB 4, 95% CI 3 to 6; I2 = 0%; 2 studies; 381 infants; moderate-certainty evidence) and on BPD at 36 weeks' PMA. No evidence of harmful effects was found. There was little evidence for effects of different starting doses or timing of systemic corticosteroids on death or BPD at 36 weeks' PMA, but potential adverse effects were observed for some comparisons. Lowering the dose might result in a more unfavourable balance of benefits and harms. Moderately early initiated systemic corticosteroids, compared with early systemic corticosteroids, may result in a higher incidence of BPD at 36 weeks' PMA. Pulse dosing instead of continuous dosing may have a negative effect on death and BPD at 36 weeks' PMA. We found no differences for the comparisons of inhaled versus systemic corticosteroids. AUTHORS' CONCLUSIONS: This overview summarises the evidence of nine SRs investigating the effect of postnatal corticosteroids in preterm infants at risk for BPD. Late initiated (≥ seven days after birth) systemic administration of dexamethasone is considered an effective intervention to reduce the risk of BPD in infants with a high risk profile for BPD, based on a favourable balance between benefits and harms. Endotracheal instillation of corticosteroids (budesonide) with surfactant as a carrier is a promising intervention, based on the beneficial effect on desirable outcomes without (so far) negative side effects. Pending results of ongoing large, multicentre RCTs investigating both short- and long-term effects, endotracheal instillation of corticosteroids (budesonide) with surfactant as a carrier is not appropriate for clinical practice at present. Early initiated (< seven days after birth) systemic dexamethasone and hydrocortisone and late initiated (≥ seven days after birth) hydrocortisone are considered ineffective interventions, because of an unfavourable balance between benefits and harms. No conclusions are possible regarding early and late inhaled corticosteroids, as more research is needed.


Assuntos
Displasia Broncopulmonar , Glucocorticoides , Recém-Nascido , Lactente , Humanos , Displasia Broncopulmonar/tratamento farmacológico , Displasia Broncopulmonar/prevenção & controle , Anti-Inflamatórios/efeitos adversos , Hidrocortisona/uso terapêutico , Dexametasona , Revisões Sistemáticas como Assunto , Budesonida , Tensoativos
2.
Pediatr Res ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565917

RESUMO

Chronic lung disease of prematurity or bronchopulmonary dysplasia (BPD) is a common complication of preterm birth. Nutrition may affect incidence and severity of BPD. In this context, the Section on Nutrition, Gastroenterology and Metabolism, the Pulmonary Section of the European Society for Paediatric Research (ESPR) and SPR have joined forces to review the current knowledge on nutritional issues related to BPD. The aim of this narrative review is to discuss the clinical implications for nutritional practice. Nutrient deficiencies may influence pathogenesis of BPD. Adequate nutrition and growth can play a crucial role in the prevention of and recovery from BPD. Optimal nutrition strategy is an important principle, especially in the early postnatal period. As optimal energy intake in infants at risk of BPD or with evolving BPD is not yet defined, further research with well-designed studies on nutritional strategies for preterm infants with BPD is urgently needed. IMPACT: Based on current evidence it seems reasonable to recommend that BPD diagnosed infants should receive an energy supply ranging from 120 to 150 Kcal/kg/d. Exclusive MOM feed with adequate fortification should be encouraged as this is associated with a significant reduction in the risk of BPD. Suboptimal nutritional delivery is often seen in preterm infants with BPD compared to controls.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38604653

RESUMO

OBJECTIVE: Regarding the use of lung ultrasound (LU) in neonatal intensive care units (NICUs) across Europe, to assess how widely it is used, for what indications and how its implementation might be improved. DESIGN AND INTERVENTION: International online survey. RESULTS: Replies were received from 560 NICUs in 24 countries between January and May 2023. LU uptake varied considerably (20%-98% of NICUs) between countries. In 428 units (76%), LU was used for clinical indications, while 34 units (6%) only used it for research purposes. One-third of units had <2 years of experience, and only 71 units (13%) had >5 years of experience. LU was mainly performed by neonatologists. LU was most frequently used to diagnose respiratory diseases (68%), to evaluate an infant experiencing acute clinical deterioration (53%) and to guide surfactant treatment (39%). The main pathologies diagnosed by LU were pleural effusion, pneumothorax, transient tachypnoea of the newborn and respiratory distress syndrome. The main barriers for implementation were lack of experience with technical aspects and/or image interpretation. Most units indicated that specific courses and an international guideline on neonatal LU could promote uptake of this technique. CONCLUSIONS: Although LU has been adopted in neonatal care in most European countries, the uptake is highly variable. The main indications are diagnosis of lung disease, evaluation of acute clinical deterioration and guidance of surfactant. Implementation may be improved by developing courses and publishing an international guideline.

4.
PEC Innov ; 4: 100270, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38495319

RESUMO

Objective: To obtain insights into parents' information needs during the first year at home with their very preterm (VP) born infant. Methods: We conducted semi-structured interviews with parents of VP infants participating in a post-discharge responsive parenting intervention (TOP program). Online interviews were audiotaped and transcribed verbatim. Inductive thematic analysis was performed by two independent coders. Results: Ten participants were interviewed and had various and changing information needs during the developmental trajectory of their infant. Three main themes emerged; (1) Help me understand and cope, (2) Be fully responsible for my baby, and (3) Teach me to do it myself. Available and used sources, such as the Internet, did not meet their information needs. Participants preferred their available and knowledgeable healthcare professionals for reassurance, tailored information, and practical guidance. Conclusion: This study identified parents' information needs during the first year at home with their VP infant and uncovered underlying re-appearing needs to gain confidence in child-caring abilities and autonomy in decision-making about their infants' care. Innovation: This study provides valuable information for healthcare professionals and eHealth developers to support parental self-efficacy during the first year after preterm birth.

5.
Semin Perinatol ; 48(2): 151887, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38556386

RESUMO

High frequency ventilation (HFV) in neonates has been in use for over forty years. Some early HFV ventilators are no longer available, but high frequency oscillatory ventilation (HFOV) and jet ventilators (HFJV) continue to be commonly employed. Advanced HFOV models available outside of the United States are much quieter and easier to use, and are available as options on many conventional ventilators, providing important improvements such as tidal volume measurement and targeting. HFJV excels in treating air leak and non-homogenous lung disease and is often used for other diseases as well. High frequency non-invasive ventilation (hfNIV) is a novel application of HFV that remains under investigation. Similar to bubble CPAP, hfNIV has been applied with a variety of high-frequency ventilators. Efficacy and safety of hfNIV with any device have not yet been established. This article describes the current approaches to these HFV therapies and stresses the importance of understanding how each device works and what disease processes may respond best to the technology employed.


Assuntos
Ventilação de Alta Frequência , Ventilação não Invasiva , Recém-Nascido , Humanos , Respiração Artificial , Volume de Ventilação Pulmonar
6.
Pediatr Res ; 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493255

RESUMO

BACKGROUND: Postnatal systemic corticosteroids reduce the risk of bronchopulmonary dysplasia but the effect depends on timing, dosing, and type of corticosteroids. Animal studies may provide valuable information on these variable effects. This systematic review summarizes the effects of postnatal systemic corticosteroids on lung development in newborn animals. METHODS: A systematic search was performed in PubMed and Embase in December 2022. The protocol was published on PROSPERO (CRD42021177701). RESULTS: Of the 202 eligible studies, 51 were included. Only newborn rodent studies met the inclusion criteria. Most studies used dexamethasone (98%). There was huge heterogeneity in study outcome measures and corticosteroid treatment regimens. Reporting of study quality indicators was mediocre and risk of bias was unclear due to poor reporting of study methodology. Meta-analysis showed that postnatal corticosteroids caused a decrease in body weight as well as persistent alveolar simplification. Subgroup analyses revealed that healthy animals were most affected. CONCLUSION: In newborn rodents, postnatal systemic corticosteroids have a persistent negative effect on body weight and lung development. There was huge heterogeneity in experimental models, mediocre study quality, unclear risk of bias, and very small subgroups for meta-analysis which limited firm conclusions. IMPACT: Postnatal corticosteroids reduce the risk of bronchopulmonary dysplasia but the effect depends on timing, dosing, and type of corticosteroids while the underlying mechanism of this variable effect is unknown. This is the first systematic review and meta-analysis of preclinical newborn animal studies reviewing the effect of postnatal systemic corticosteroids on lung development. In newborn rodent models, postnatal corticosteroids have a persistent negative effect on body weight and lung alveolarization, especially in healthy animals.

7.
Trials ; 25(1): 164, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38439024

RESUMO

BACKGROUND: Mortality, cerebral injury, and necrotizing enterocolitis (NEC) are common complications of very preterm birth. An important risk factor for these complications is hemodynamic instability. Pre-clinical studies suggest that the timing of umbilical cord clamping affects hemodynamic stability during transition. Standard care is time-based cord clamping (TBCC), with clamping irrespective of lung aeration. It is unknown whether delaying cord clamping until lung aeration and ventilation have been established (physiological-based cord clamping, PBCC) is more beneficial. This document describes the statistical analyses for the ABC3 trial, which aims to assess the efficacy and safety of PBCC, compared to TBCC. METHODS: The ABC3 trial is a multicenter, randomized trial investigating PBCC (intervention) versus TBCC (control) in very preterm infants. The trial is ethically approved. Preterm infants born before 30 weeks of gestation are randomized after parental informed consent. The primary outcome is intact survival, defined as the composite of survival without major cerebral injury and/or NEC. Secondary short-term outcomes are co-morbidities and adverse events assessed during NICU admission, parental reported outcomes, and long-term neurodevelopmental outcomes assessed at a corrected age of 2 years. To test the hypothesis that PBCC increases intact survival, a logistic regression model will be estimated using generalized estimating equations (accounting for correlation between siblings and observations in the same center) with treatment and gestational age as predictors. This plan is written and submitted without knowledge of the data. DISCUSSION: The findings of this trial will provide evidence for future clinical guidelines on optimal cord clamping management at birth. TRIAL REGISTRATION: ClinicalTrials.gov NCT03808051. Registered on 17 January 2019.


Assuntos
Recém-Nascido Prematuro , Nascimento Prematuro , Lactente , Feminino , Recém-Nascido , Humanos , Pré-Escolar , Constrição , Recém-Nascido de muito Baixo Peso , Respiração
8.
Br J Clin Pharmacol ; 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38450797

RESUMO

AIMS: Little is known about the population pharmacokinetics (PPK) of vancomycin in neonates with perinatal asphyxia treated with therapeutic hypothermia (TH). We aimed to describe the PPK of vancomycin and propose an initial dosing regimen for the first 48 h of treatment with pharmacokinetic/pharmacodynamic target attainment. METHODS: Neonates with perinatal asphyxia treated with TH were included from birth until Day 6 in a multicentre prospective cohort study. A vancomycin PPK model was constructed using nonlinear mixed-effects modelling. The model was used to evaluate published dosing guidelines with regard to pharmacokinetic/pharmacodynamic target attainment. The area under the curve/minimal inhibitory concentration ratio of 400-600 mg*h/L was used as target range. RESULTS: Sixteen patients received vancomycin (median gestational age: 41 [range: 38-42] weeks, postnatal age: 4.4 [2.5-5.5] days, birth weight: 3.5 [2.3-4.7] kg), and 112 vancomycin plasma concentrations were available. Most samples (79%) were collected during the rewarming and normothermic phase, as vancomycin was rarely initiated during the hypothermic phase due to its nonempirical use. An allometrically scaled 1-compartment model showed the best fit. Vancomycin clearance was 0.17 L/h, lower than literature values for term neonates of 3.5 kg without perinatal asphyxia (range: 0.20-0.32 L/h). Volume of distribution was similar. Published dosing regimens led to overexposure within 24 h of treatment. A loading dose of 10 mg/kg followed by 24 mg/kg/day in 4 doses resulted in target attainment. CONCLUSION: Results of this study suggest that vancomycin clearance is reduced in term neonates with perinatal asphyxia treated with TH. Lower dosing regimens should be considered followed by model-informed precision dosing.

9.
Pediatr Neurol ; 153: 152-158, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38387280

RESUMO

OBJECTIVE: To investigate the association between the presence and severity of seizures in asphyxiated newborns and their neurodevelopmental outcome at ages two and five years. METHODS: Retrospective data analysis from a prospectively collected multicenter cohort of 186 term-born asphyxiated newborns undergoing therapeutic hypothermia (TH) in 11 centers in the Netherlands and Belgium. Seizures were diagnosed by amplitude-integrated electroencephalography (EEG) and raw EEG signal reading up to 48 hours after rewarming. Neurodevelopmental outcome was assessed by standardized testing at age two and five years. Primary outcome was death or long-term neurodevelopmental impairment (NDI) including cerebral palsy. Associations were calculated using univariate and multivariate logistic regression analyses adjusting for Thompson score and a validated brain magnetic resonance imaging (MRI) score. RESULTS: Seventy infants (38%) had seizures during TH or rewarming, and 44 (63%) of these needed two or more antiseizure medications (ASMs). Overall mortality was 21%. Follow-up data from 147 survivors were available for 137 infants (93%) at two and for 94 of 116 infants (81%) at five years. NDI was present in 26% at two and five years. Univariate analyses showed a significant association between seizures and death or NDI, but this was no longer significant after adjusting for Thompson and MRI score in the multivariate analysis; this was also true for severe seizures (need for two or more ASMs) or seizures starting during rewarming. CONCLUSION: The presence or severity of seizures in newborns undergoing TH for hypoxic-ischemic encephalopathy was not independently associated with death or NDI up to age five years after adjusting for several confounders.


Assuntos
Asfixia Neonatal , Hipotermia Induzida , Hipóxia-Isquemia Encefálica , Doenças do Recém-Nascido , Acidente Vascular Cerebral , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Asfixia Neonatal/complicações , Asfixia Neonatal/terapia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Eletroencefalografia/métodos , Hipotermia Induzida/métodos , Hipóxia-Isquemia Encefálica/terapia , Doenças do Recém-Nascido/terapia , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Convulsões/etiologia , Convulsões/complicações , Acidente Vascular Cerebral/complicações , Estudos Multicêntricos como Assunto
10.
Ther Drug Monit ; 46(3): 376-383, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38287875

RESUMO

BACKGROUND: Model validation procedures are crucial when population pharmacokinetic (PK) models are used to develop dosing algorithms and to perform model-informed precision dosing. We have previously published a population PK model describing the PK of gentamicin in term neonates with perinatal asphyxia during controlled therapeutic hypothermia (TH), which showed altered gentamicin clearance during the hypothermic phase dependent on gestational age and weight. In this study, the predictive performance and generalizability of this model were assessed using an independent data set of neonates with perinatal asphyxia undergoing controlled TH. METHODS: The external data set contained a subset of neonates included in the prospective observational multicenter PharmaCool Study. Predictive performance was assessed by visually inspecting observed-versus-predicted concentration plots and calculating bias and precision. In addition, simulation-based diagnostics, model refitting, and bootstrap analyses were performed. RESULTS: The external data set included 323 gentamicin concentrations of 39 neonates. Both the model-building and external data set included neonates from multiple centers. The original gentamicin PK model predicted the observed gentamicin concentrations with adequate accuracy and precision during all phases of controlled TH. Model appropriateness was confirmed with prediction-corrected visual predictive checks and normalized prediction distribution error analyses. Model refitting to the merged data set (n = 86 neonates with 935 samples) showed accurate estimation of PK parameters. CONCLUSIONS: The results of this external validation study justify the generalizability of the gentamicin dosing recommendations made in the original study for neonates with perinatal asphyxia undergoing controlled TH (5 mg/kg every 36 or 24 h with gestational age 36-41 and 42 wk, respectively) and its applicability in model-informed precision dosing.


Assuntos
Antibacterianos , Asfixia Neonatal , Gentamicinas , Hipotermia Induzida , Modelos Biológicos , Humanos , Gentamicinas/farmacocinética , Gentamicinas/uso terapêutico , Recém-Nascido , Hipotermia Induzida/métodos , Asfixia Neonatal/terapia , Estudos Prospectivos , Antibacterianos/farmacocinética , Antibacterianos/uso terapêutico , Masculino , Feminino , Idade Gestacional
11.
Neonatology ; 121(1): 125-132, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37852207

RESUMO

INTRODUCTION: The objective of this study was to identify risk factors for neurodevelopmental impairment (NDI) at 2- and 5-years corrected age (CA) in a cohort of preterm infants with established bronchopulmonary dysplasia (BPD). METHODS: This single-center retrospective cohort study included infants born between 2009 and 2016 at a gestational age (GA) <30 weeks with moderate or severe BPD at 36 weeks' postmenstrual age. Perinatal characteristics, (social) demographics, and comorbidities were collected from the electronic patient records. Odds ratios for NDI were calculated with univariate and multivariate logistic regression analyses adjusting for potential confounders. RESULTS: Of the 602 eligible infants, 123 infants were diagnosed with BPD. NDI was present in 30.3% and 56.1% at 2- and 5-years CA, respectively. The only independent risk factors associated with NDI in the multivariate analyses were birthweight (adjusted odds ratio [aOR] 0.74, 95% CI 0.57-0.95; aOR 0.70, 95% CI 0.54-0.91, respectively), small for GA (SGA) (aOR 3.25, 95% CI 1.09-9.61; aOR 5.44, 95% CI 1.62-18.2, respectively) at both time points, and male gender at 5-years CA (OR 2.49, 95% CI 1.11-5.57). CONCLUSION: Birthweight and SGA are independent risk factors for NDI at 2- and 5-years CA and male gender at 5-years CA in preterm infants with BPD. In contrast, well-known other risk factors for NDI in the general population of preterm infants, such as GA, maternal education, and neonatal comorbidities were not independently associated with NDI.


Assuntos
Displasia Broncopulmonar , Recém-Nascido Prematuro , Lactente , Gravidez , Feminino , Humanos , Recém-Nascido , Masculino , Displasia Broncopulmonar/epidemiologia , Displasia Broncopulmonar/etiologia , Estudos Retrospectivos , Peso ao Nascer , Idade Gestacional , Fatores de Risco
12.
Arch Dis Child Fetal Neonatal Ed ; 109(2): 159-165, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-37722765

RESUMO

OBJECTIVE: To explore clinical effect modifiers of systemic hydrocortisone in ventilated very preterm infants for survival and neurodevelopmental outcome at 2 years' corrected age (CA). DESIGN: Secondary analysis of a randomised placebo-controlled trial. SETTING: Dutch and Belgian neonatal intensive care units. PATIENTS: Infants born <30 weeks' gestational age (GA), ventilator-dependent in the second week of postnatal life. INTERVENTION: Infants were randomly assigned to systemic hydrocortisone (cumulative dose 72.5 mg/kg; n=182) or placebo (n=190). MAIN OUTCOME MEASURES: The composite of death or neurodevelopmental impairment (NDI) at 2 years' CA and its components. Candidate effect modifiers (GA, small for GA, respiratory index, sex, multiple births, risk of moderate/severe bronchopulmonary dysplasia or death) were analysed using regression models with interaction terms and subpopulation treatment effect pattern plots. RESULTS: The composite outcome was available in 356 (96.0%) of 371 patients (one consent withdrawn). For this outcome, treatment effect heterogeneity was seen across GA subgroups (<27 weeks: hydrocortisone (n=141) vs placebo (n=156), 54.6% vs 66.2%; OR 0.61 (95% CI 0.38 to 0.98); ≥27 weeks: hydrocortisone (n=30) vs placebo (n=31), 66.7% vs 45.2%; OR 2.43 (95% CI 0.86 to 6.85); p=0.02 for interaction). This effect was also found for the component death (<27 weeks: 20.1% vs 32.1%; OR 0.53 (95% CI 0.32 to 0.90); ≥27 weeks: 28.1% vs 16.1%; OR 2.04 (95% CI 0.60 to 6.95); p=0.049 for interaction) but not for the component NDI. No differential treatment effects were observed across other subgroups. CONCLUSION: This secondary analysis suggests that in infants <27 weeks' GA, systemic hydrocortisone may improve the outcome death or NDI, mainly driven by its component death. There was insufficient evidence for other selected candidate effect modifiers.


Assuntos
Displasia Broncopulmonar , Doenças do Prematuro , Lactente , Recém-Nascido , Humanos , Hidrocortisona , Recém-Nascido Prematuro , Recém-Nascido de muito Baixo Peso , Glucocorticoides/uso terapêutico , Doenças do Prematuro/tratamento farmacológico
13.
Pediatr Res ; 95(1): 52-58, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37660179

RESUMO

Preterm infants often experience breathing instability and a hampered lung function. Therefore, these infants receive cardiorespiratory monitoring and respiratory support. However, the current respiratory monitoring technique may be unreliable for especially obstructive apnea detection and classification and it does not provide insight in breathing effort. The latter makes the selection of the adequate mode and level of respiratory support difficult. Electromyography of the diaphragm (dEMG) has the potential of monitoring heart rate (HR) and respiratory rate (RR), and it provides additional information on breathing effort. This review summarizes the available evidence on the clinical potential of dEMG to provide cardiorespiratory monitoring, to synchronize patient-ventilator interaction, and to optimize the mode and level of respiratory support in the individual newborn infant. We also try to identify gaps in knowledge and future developments needed to ensure widespread implementation in clinical practice. IMPACT: Preterm infants require cardiorespiratory monitoring and respiratory support due to breathing instability and a hampered lung function. The current respiratory monitoring technique may provide unreliable measurements and does not provide insight in breathing effort, which makes the selection of the optimal respiratory support settings difficult. Measuring diaphragm activity could improve cardiorespiratory monitoring by providing insight in breathing effort and could potentially have an important role in individualizing respiratory support in newborn infants.


Assuntos
Diafragma , Recém-Nascido Prematuro , Lactente , Humanos , Recém-Nascido , Diafragma/fisiologia , Eletromiografia , Estudos Prospectivos , Taxa Respiratória/fisiologia
14.
Arch Dis Child Fetal Neonatal Ed ; 109(2): 221-226, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-37827816

RESUMO

OBJECTIVE: This randomised study in preterm infants on non-invasive respiratory support investigated the effectiveness of automated oxygen control (A-FiO2) in keeping the oxygen saturation (SpO2) within a target range (TR) during a 28-day period compared with manual titration (M-FiO2). DESIGN: A single-centre randomised control trial. SETTING: A level III neonatal intensive care unit. PATIENTS: Preterm infants (<28 weeks' gestation) on non-invasive respiratory support. INTERVENTIONS: A-FiO2 versus M-FiO2 control. METHODS: Main outcomes were the proportion of time spent and median area of episodes in the TR, hyperoxaemia, hypoxaemia and the trend over 28 days using a linear random intercept model. RESULTS: 23 preterm infants (median gestation 25.7 weeks; birth weight 820 g) were randomised. Compared with M-FiO2, the time spent within TR was higher in the A-FiO2 group (68.7% vs 48.0%, p<0.001). Infants in the A-FiO2 group spent less time in hyperoxaemia (13.8% vs 37.7%, p<0.001), but no difference was found in hypoxaemia. The time-based analyses showed that the A-FiO2 efficacy may differ over time, especially for hypoxaemia. Compared with the M-FiO2 group, the A-FiO2 group had a larger intercept but with an inversed slope for the daily median area below the TR (intercept 70.1 vs 36.3; estimate/day -0.70 vs 0.69, p<0.001). CONCLUSION: A-FiO2 control was superior to manual control in keeping preterm infants on non-invasive respiratory support in a prespecified TR over a period of 28 days. This improvement may come at the expense of increased time below the TR in the first days after initiating A-FiO2 control. TRIAL REGISTRATION NUMBER: NTR6731.


Assuntos
Recém-Nascido Prematuro , Oxigênio , Lactente , Recém-Nascido , Humanos , Estudos Cross-Over , Peso ao Nascer , Hipóxia/prevenção & controle
15.
J Pediatr ; 265: 113807, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37923196

RESUMO

OBJECTIVE: To evaluate whether a high cumulative dose of systemic hydrocortisone affects brain development compared with placebo when initiated between 7 and 14 days after birth in ventilated infants born preterm. STUDY DESIGN: A double-blind, placebo-controlled, randomized trial was conducted in 16 neonatal intensive care units among infants born at <30 weeks of gestation or with a birth weight of <1250 g who were ventilator-dependent in the second week after birth. Three centers performed MRI at term-equivalent age. Brain injury was assessed on MRI using the Kidokoro scoring system and compared between the 2 treatment groups. Both total and regional brain volumes were calculated using an automatic segmentation method and compared using multivariable regression analysis adjusted for baseline variables. RESULTS: From the 3 centers, 78 infants participated in the study and 59 had acceptable MRI scans (hydrocortisone group, n = 31; placebo group, n = 28). Analyses of the median global brain abnormality score of the Kidokoro score showed no difference between the hydrocortisone and placebo groups (median, 7; IQR, 5-9 vs median, 8, IQR, 4-10, respectively; P = .92). In 39 infants, brain tissue volumes were measured, showing no differences in the adjusted mean total brain tissue volumes, at 352 ± 32 mL in the hydrocortisone group and 364 ± 51 mL in the placebo group (P = .80). CONCLUSIONS: Systemic hydrocortisone started in the second week after birth in ventilator-dependent infants born very preterm was not found to be associated with significant differences in brain development compared with placebo treatment. TRIAL REGISTRATION: The SToP-BPD study was registered with the Netherlands Trial Register (NTR2768; registered on 17 February 2011; https://www.trialregister.nl/trial/2640) and the European Union Clinical Trials Register (EudraCT, 2010-023777-19; registered on 2 November 2010; https://www.clinicaltrialsregister.eu/ctr-search/trial/2010-023777-19/NL).


Assuntos
Displasia Broncopulmonar , Hidrocortisona , Recém-Nascido , Lactente , Humanos , Recém-Nascido Prematuro , Displasia Broncopulmonar/tratamento farmacológico , Ventiladores Mecânicos , Encéfalo/diagnóstico por imagem
16.
Semin Fetal Neonatal Med ; 28(6): 101495, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38012889

RESUMO

The introduction of exogenous surfactant in the 1980s has resulted in an improved survival of very preterm infants with respiratory distress syndrome (RDS). Randomized controlled trials conducted before 2000 have shown that the magnitude of this beneficial effect strongly depends on the timing of surfactant treatment, i.e. the earlier surfactant is administered after birth the better. However, the initial mode of respiratory support in infants with RDS has changed dramatically over the last decades, moving from invasive to non-invasive support. Furthermore, new, less invasive techniques to administer surfactant have been introduced to match this non-invasive approach. This review summarizes the evidence on how these practice changes impacted the effect of surfactant timing on mortality and morbidity in preterm infants with RDS.


Assuntos
Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Lactente , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Tensoativos/uso terapêutico , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Surfactantes Pulmonares/uso terapêutico , Respiração Artificial/métodos , Pressão Positiva Contínua nas Vias Aéreas/métodos , Lipoproteínas/uso terapêutico
17.
Sci Rep ; 13(1): 20842, 2023 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-38012186

RESUMO

Endotracheal suctioning is a widely used procedure to remove secretions from the airways of ventilated patients. Despite its prevalence, regional effects of this maneuver have seldom been studied. In this study, we explore its effects on regional lung aeration in neonates and young infants using electrical impedance tomography (EIT) as part of the large EU-funded multicenter observational study CRADL. 200 neonates and young infants in intensive care units were monitored with EIT for up to 72 h. EIT parameters were calculated to detect changes in ventilation distribution, ventilation inhomogeneity and ventilation quantity on a breath-by-breath level 5-10 min before and after suctioning. The intratidal change in aeration over time was investigated by means of regional expiratory time constants calculated from all respiratory cycles using an innovative procedure and visualized by 2D maps of the thoracic cross-section. 344 tracheal suctioning events from 51 patients could be analyzed. They showed no or very small changes of EIT parameters, with a dorsal shift of the center of ventilation by 0.5% of the chest diameter and a 7% decrease of tidal impedance variation after suctioning. Regional time constants did not change significantly. Routine suctioning led to EIT-detectable but merely small changes of the ventilation distribution in this study population. While still a measure requiring further study, the time constant maps may help clinicians interpret ventilation mechanics in specific cases.


Assuntos
Estado Terminal , Tomografia , Recém-Nascido , Humanos , Lactente , Impedância Elétrica , Sucção , Tomografia/métodos , Pulmão/diagnóstico por imagem
19.
Trials ; 24(1): 656, 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37817255

RESUMO

BACKGROUND: Apnoea of prematurity (AOP) is one of the most common diagnoses among preterm infants. AOP often leads to hypoxemia and bradycardia which are associated with an increased risk of death or disability. In addition to caffeine therapy and non-invasive respiratory support, doxapram might be used to reduce hypoxemic episodes and the need for invasive mechanical ventilation in preterm infants, thereby possibly improving their long-term outcome. However, high-quality trials on doxapram are lacking. The DOXA-trial therefore aims to investigate the safety and efficacy of doxapram compared to placebo in reducing the composite outcome of death or severe disability at 18 to 24 months corrected age. METHODS: The DOXA-trial is a double blinded, multicentre, randomized, placebo-controlled trial conducted in the Netherlands, Belgium and Canada. A total of 396 preterm infants with a gestational age below 29 weeks, suffering from AOP unresponsive to non-invasive respiratory support and caffeine will be randomized to receive doxapram therapy or placebo. The primary outcome is death or severe disability, defined as cognitive delay, cerebral palsy, severe hearing loss, or bilateral blindness, at 18-24 months corrected age. Secondary outcomes are short-term neonatal morbidity, including duration of mechanical ventilation, bronchopulmonary dysplasia and necrotising enterocolitis, hospital mortality, adverse effects, pharmacokinetics and cost-effectiveness. Analysis will be on an intention-to-treat principle. DISCUSSION: Doxapram has the potential to improve neonatal outcomes by improving respiration, but the safety concerns need to be weighed against the potential risks of invasive mechanical ventilation. It is unknown if the use of doxapram improves the long-term outcome. This forms the clinical equipoise of the current trial. This international, multicentre trial will provide the needed high-quality evidence on the efficacy and safety of doxapram in the treatment of AOP in preterm infants. TRIAL REGISTRATION: ClinicalTrials.gov NCT04430790 and EUDRACT 2019-003666-41. Prospectively registered on respectively June and January 2020.


Assuntos
Displasia Broncopulmonar , Doxapram , Humanos , Lactente , Recém-Nascido , Cafeína/efeitos adversos , Doxapram/efeitos adversos , Idade Gestacional , Recém-Nascido Prematuro , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Método Duplo-Cego
20.
Pediatr Pulmonol ; 58(12): 3574-3581, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37795597

RESUMO

INTRODUCTION: We determined if the heart rate (HR) monitoring performance of a wireless and nonadhesive belt is non-inferior compared to standard electrocardiography (ECG). Secondary objective was to explore the belt's respiratory rate (RR) monitoring performance compared to chest impedance (CI). METHOD: In this multicenter non-inferiority trial, preterm and term infants were simultaneously monitored with the belt and conventional ECG/CI for 24 h. HR monitoring performance was estimated with the HR difference and ability to detect cardiac events compared to the ECG, and the incidence of HR-data loss per second. These estimations were statistically compared to prespecified margins to confirm equivalence/non-inferiority. Exploratory RR analyses estimated the RR trend difference and ability to detect apnea/tachypnea compared to CI, and the incidence of RR-data loss per second. RESULTS: Thirty-nine infants were included. HR monitoring with the belt was non-inferior to the ECG with a mean HR difference of 0.03 beats per minute (bpm) (standard error [SE] = 0.02) (95% limits of agreement [LoA]: [-5 to 5] bpm) (p < 0.001). Second, sensitivity and positive predictive value (PPV) for cardiac event detection were 94.0% (SE = 0.5%) and 92.6% (SE = 0.6%), respectively (p ≤ 0.001). Third, the incidence of HR-data loss was 2.1% (SE = 0.4%) per second (p < 0.05). The exploratory analyses of RR showed moderate trend agreement with a mean RR-difference of 3.7 breaths/min (SE = 0.8) (LoA: [-12 to 19] breaths/min), but low sensitivities and PPV's for apnea/tachypnea detection. The incidence of RR-data loss was 2.2% (SE = 0.4%) per second. CONCLUSION: The nonadhesive, wireless belt showed non-inferior HR monitoring and a moderate agreement in RR trend compared to ECG/CI. Future research on apnea/tachypnea detection is required.


Assuntos
Apneia , Diafragma , Humanos , Lactente , Recém-Nascido , Apneia/diagnóstico , Apneia/epidemiologia , Diafragma/fisiologia , Monitorização Fisiológica , Taxa Respiratória/fisiologia , Taquipneia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA